Advanced Setup
These parameters are activated when you set the Link Type to Dialup
BOD. Usually the ISDN will use one B channel to access the Internet
or remote network when you use the Dialup BOD link type. The router
will use the parameters here to make a decision on when to activate/
drop the additional B channel. Note that cps (characters-per-second)
measures the total link utilization.
High Water Mark and High Water Time: These parameters
specify the conditions under which the second channel will be
activated. When the utilization of the first connected channel
goes over the High Water Mark and past the High Water Time,
the additional channel will be activated. The link speed will
then be 128kbps (two B channels).
Low Water Mark and Low Water Time: These parameters
specify the conditions under which the second channel will be
dropped. When the two B channel’s utilization is under the
Low Water Mark and past the High Water Time, the additional
channel will be dropped. The link speed will be 64kbps (one B
channel).
Note:
If you are not familiar with ISDN and ML-PPP’s opera-
tion, be wary of changing the default values.
Click “OK”.